Biaxial Pliastic Geogrid for Road Stabilization Project in Ethiopia
CASE · 2025-11-08 · 0 views

Biaxial plastic geogrid is made by extruding polymers into sheets, punching holes, and then stretching the sheets both lengthwise and crosswise. It features high tensile strength in both directions, and its structure creates a robust interlocking system in soil to realize effective load bearing and diffusion, which fits large-area permanent load-bearing needs well.
A specific type of plastic geogrid, the biaxial version is a square or rectangular polymer mesh made by stretching. Based on different stretching directions in production, plastic geogrids are split into uniaxial and biaxial types. The production process involves punching extruded polymer sheets (usually polypropylene or high-density polyethylene) and then conducting directional stretching under heat. Uniaxial geogrids are stretched only along the sheet length, while biaxial ones are made by re-stretching uniaxial grids in the perpendicular direction.
In the heating and stretching stages of manufacturing, the polymer molecules of the biaxial plastic geogrid rearrange and align, which boosts intermolecular bonding and improves the product’s strength. Its elongation is just 10%–15% of the original sheet. Adding anti-aging materials like carbon black can also enhance its durability, making it resistant to acids, alkalis, corrosion and aging.
Biaxial plastic geogrid is suitable for a wide range of reinforcement works, including dams, roadbeds, slope protection and tunnel wall reinforcement. It is also applied to reinforce permanent load-bearing foundations of large airports, parking lots, docks and freight yards.
CASE STUDY
Location – Ethiopia
Product(s) – Biaxial Pliastic Geogrid
Application – Road stabilization

Issue
The road construction project site had issues such as poor foundation bearing capacity, soil subsidence, and a pavement covered with cracks of different sizes. The tender required the construction to be completed within one and a half months. Our Thai client secured the bid for this project, and planned to use HDPE geogrids to address the problems of uneven roads and extensive cracking. According to the client’s technical indicators, we proposed a 50kN-50kN biaxial plastic geogrid, with a total quantity of 29,000 square meters to be delivered in one 40HQ container. After several days of communication and confirmation of key details like price, delivery time and packaging, the client initiated the procurement process.
Why use HDPE geogrid for road stabilization?
HDPE geogrid ranks as a key geosynthetic product, boasting distinctive performance traits and functional advantages that set it apart from other geosynthetic materials. It is widely applied as a reinforcing component in reinforced soil structures, as well as a strengthening layer in composite material systems, with the following core characteristics.
Biaxial plastic geogrid features high tensile strength and minimal creep deformation, enabling it to adapt to diverse soil conditions across different environments. This makes it fully capable of meeting the construction requirements for high retaining walls in high-grade highways. The geogrid structure effectively enhances the interlocking and intermeshing effects of the reinforced bearing interface, significantly boosting the foundation’s load-bearing capacity, effectively restricting lateral soil displacement, and improving overall foundation stability.
In contrast to conventional geogrids, this product delivers superior performance: higher structural strength, greater load-bearing capacity, excellent corrosion resistance, good aging resistance, a large friction coefficient, uniform aperture distribution, straightforward construction procedures, and an extended service life.
Biaxial plastic geogrid is particularly well-suited for deep-sea engineering projects and embankment reinforcement projects. It fundamentally addresses the technical flaws of traditional gabions made from alternative materials—such as insufficient strength, poor corrosion resistance, and short service life—caused by long-term seawater erosion. Additionally, it effectively prevents construction damage that may occur due to mechanical crushing and wear during the installation process.

Application Field of HDPE Geogrid Fabric
1. Product Application Scope
Standard geogrid fabric is engineered for subgrade and pavement reinforcement across a wide range of infrastructure projects, including highways, railways, and airport runways.
HDPE geogrid fabric excels in foundation stabilization for permanent heavy-load structures, such as large-scale parking facilities and dock freight yards.
This HDPE geogrid variant also serves as an effective solution for slope protection along railway and highway corridors.
It can be deployed for secondary reinforcement of soil slopes that have already been strengthened with uniaxial tensile geogrids, delivering enhanced slope stability and mitigating soil erosion risks.
In general, geogrids are widely applicable to embankment and subgrade reinforcement, slope protection, and tunnel wall reinforcement. They also support foundation strengthening for permanent load-bearing facilities like major airports, parking lots, and dock terminals.
2. Core Functional Advantages
Geogrids effectively boost the bearing capacity of road and ground foundations, while extending the service life of such infrastructure.
They prevent ground and pavement subsidence or cracking, helping maintain a smooth, aesthetically pleasing surface.
The product features straightforward construction procedures, reducing labor and time costs, shortening overall construction cycles, and cutting long-term maintenance expenses.
Successful implementation of geogrids is projected to minimize common embankment defects in high-intensity seismic zones, enhancing the seismic resilience and disaster reduction capabilities of road networks. However, existing highway and railway seismic design codes lack specific provisions governing the seismic performance of geogrid-reinforced embankments.
3. Standard Construction Requirements
3.1 Construction Site Preparation
The construction base must be compacted, leveled, and cleared of all sharp objects, spikes, and debris to ensure a smooth working surface.
3.2 Geogrid Laying Guidelines
On the pre-leveled and compacted site, the primary stress direction (longitudinal axis) of the geogrid should be positioned perpendicular to the embankment’s central axis. The geogrid must be laid flat, free of wrinkles, and stretched as tightly as possible, secured via anchor nails and rock-soil ballast to prevent displacement.
Full-length continuity without joints is required along the geogrid’s main stress direction. Adjacent geogrid panels can be connected via manual lacing and overlapping, with a minimum overlap width of 10cm. For multi-layer geogrid installations, adjacent layers must be staggered to optimize structural integrity.
Following large-area laying, conduct overall alignment adjustments to ensure straightness. After backfilling a single soil layer and prior to rolling, re-tension the geogrid manually or with mechanical equipment to achieve uniform stress, keeping the geogrid in a straight, loaded state within the soil mass.
3.3 Filler Selection Criteria
Fill materials should be selected in strict accordance with design specifications. Field practice confirms that most soil types are suitable for use as fill, excluding frozen soil, marsh soil, household waste, chalky soil, and diatomaceous earth.
Gravelly soil and sandy soil are the preferred fillers, as they offer stable mechanical properties and minimal sensitivity to moisture content. The maximum particle size of the filler shall not exceed 15cm, and gradation control is mandatory to ensure effective compaction.
3.4 Filler Placement & Compaction
Once the geogrid is laid and fixed, backfilling must be completed promptly, with maximum geogrid exposure time limited to 48 hours. A concurrent laying-and-backfilling workflow is also recommended for efficiency.
Backfilling should start at both ends to secure the geogrid, then progress toward the center. Compaction rolling follows a "both sides first, middle later" sequence. Rollers are prohibited from direct contact with the geogrid reinforcement, and unauthorized vehicle traffic on uncompacted reinforced sections is forbidden to avoid geogrid dislocation.
Each compacted layer should be 20–30cm thick, and compaction degree must fully meet design standards — this is a critical factor for the success of reinforced soil engineering.
3.5 Waterproofing & Drainage Measures
Comprehensive internal and external wall drainage is essential for all reinforced soil projects. Toe protection must be installed to prevent water scouring, and internal drainage systems (such as filter pipes or blind ditches) should be embedded within the soil mass.
Drainage systems must be designed for unobstructed water discharge rather than blockage, as trapped water can create long-term structural hazards.
Specification of Biaxial Pliastic Geogrid for Road Stabilization Project in Ethiopia
Total quantity – 29000 square meters
Biaxial Pliastic Geogrid Specification – 50kN-50kN
Each roll size – 95m*50m

About RONSINO
RONSINO manufactures and supplies many types of effective and state of the art geogrid, geomembrane, geotextile, and geosynthetics to over 36 countries. Our main innovative, high quality geogrid products include plastic biaxial geogrid, fiberglass geogrid, plastic uniaxial geogrid, warp knitting polyester geogrid, and steel plastic georgic mesh, etc. RONSINO brand brand high quality geosynthetic products had been certificated by the ISO9001, ISO14001,OHSAS18001 Soncap, SASO and BV, SGS and Intertek, etc.
If you have any questions or inquiries, please fill in and submit the form to contact us.



